Product Features
Solar Charge Controller
Maximum Power Point Tracking of photovoltaic(PV) module
Hybrid controller, MPPT+SOC double intelligent control
12V/24V batteries voltage automatic identification
Power switching components consist of low-loss MOSFET type transistors
Power loop adopts low-loss MOSFET type transistors in parallel
Soft switching technology is applied to reduce switching loss
Synchronous rectification technology is applied to decrease voltage drop
Multistage charging technology
Voltage and current regulation
PWM control
Load disconnection depending on SOC
Automatic load reconnection
Temperature compensation
Integrated self test
Extremely low own consumption
Electronic protection functions
Battery overvoltage shutdown
Overcharge protection
Deep discharge protection
Automatic electronic fuse
Short circuit protection of load and PV module
Overvoltage protection at PV module input
Open circuit protection without battery
Overtemperature and overload protection
Reverse polarity protection using synchronous rectification technology
Reverse current protection at night
Reverse polarity protection of battery, load and PV module
Displays and Alarms
Multi-coloured LEDs indicate operating states
Buzzer sings alarm in the case of fault operation
Operation
Operation by the button
Manual load switch
Certificates
Manufactured according to ISO 9001 and ISO 14001
Compliant with European Standards (CE)
RoHS compliant
Developed in China
Made in China
Product Series | GSC-F1224 |
Battery Voltage | 12V/24V 12V/24V Automatic Identification |
Rated Output | 60W/120W;120W/240W 180W/360W;240W/480W |
Max. Efficiency | > 98% |
Own Power Consumption | < 6mA |
Maximum Input Voltage | < 25V/50 V |
Minimum Battery Voltage | >10V |
Rated Charging Current | 5A;10A;15A;20A |
Rated Load Current | 5A;10A;15A;20A |
Battery Capacity | 7Ah ~ 500Ah |
Voltage Drop of Charge Circuit | < 0.30V |
Voltage Drop of Load Circuit | < 0.25V |
Equalization Charge Voltage | 14.7V/29.4V (Used only when battery is deep discharged) |
Buck Charge Voltage | 14.4V/28.8V |
Float Charge Voltage | 13.6V/27.2V |
Undervoltage | 11.5V/23.0V |
Deep Discharge Protection (SOC/LVD) | <30% ( 11.1V/22.2V) |
Temperature Compensation | -3mv/°C/2V |
Overload Protection, Short Circuit Protection | If the load current exceeds 1.25 times of the rated current for 60 seconds, or 1.5 times the rated current for 5 seconds, the load output will be turned off; If the load current exceeds 2 times of the rated current, the load output will be turned off immediately; |
Control Mode | PWM |
Permitted Operation Temperature Range | -20°C ~ +55°C |
Permitted Storage Temperature Range | -25°C ~ +85°C |
Dimensions L x B x H | 136×100×35 mm |
Fastening Hole Clearance | Vertical 70 mm; Horizontal 128 mm |
Installation | Wall Installation Recommended |